Summary:
SME based in North-eastern Italy has developed an innovative diagnostic device, conceived as a Point Of Care test for measuring total bilirubin concentration in whole blood samples from newborns. The companies is willing to get in contact with SMEs and R&D institutions to improve the technology currently used, in the frame of research, technical cooperation and manufacturing agreements.
Description:
Neonatal hyper-bilirubinemia occurs in more than 60% of term newborns and is characterized by a peak of serum bilirubin between the 3-5th day of life, returning to normal values in about 2 weeks. In some cases, the level of bilirubin in the blood remains too high even longer, leading to severe hyper-bilirubinemia in about 10% of the jaundice infants.If caught in time, the most common treatment is photo-therapy, but if not the baby risks to develop kernicterus, an irreversible pathology characterized by a severe disability due to neurological damage.
This creates the need for a system able to control the levels of bilirubin during the first days after birth in a simple and quick way.
Therefore a company based in North-eastern Italy has developed a test strip, where a small amount of blood is loaded and a reader analyzes the sample and shows the result.
Thanks to the easy method, the small size and the use of a battery powered reader, the system does not require availability of highly qualified staff or equipped facilities for analysis, making diagnosis and monitoring of neonatal jaundice, a simple practice even outside hospital, such as during home follow up or in physician offices.
The Italian company looks for SMES, R&D institutions and universities that could be interested in cooperation in terms of:
-Research: development of a method for correction of hemoglobin interference on Bilistick results.
- Technical: the Bilistick reader uses the same electronics since 8 years ago.Tthe company looks for a cooperation that allows the re-desinging of the electronics, updating the reader according to the current electronic technology.
- Manufacturing: the company looks for a partner to re-desing the new Bilistick version from aesthetic and usability point of view.
Type (e.g. company, R&D institution…), field of industry and Role of Partner Sought:
They company is looking for SMES, R&D institutions and universities that could be interested in cooperation in terms of development of new versions of the company products, improving the technology currently used.
In details:
- Company looks for partners that could be interested in cooperation on the development of a new version of the Bilistick System in terms of:
- Research: Development of a method for correction of hemoglobin interference on Bilistick results.
- Technical: The Bilistick reader use the same electronics since 8 years ago. the company looks for a cooperation that allows the re-desing the electronics, updating the reader according with current electronic technology.
- Manufacturing: they look for a partner to re-desing the new Bilistick version from aesthetic and usability point of view. .
Stage of Development:
Already on the market
IPR Status:
Patent(s) applied for but not yet granted
External code:
TOIT20210714002